Product Details:
|
Physical Condition: | Liquid, Solid | Liquid Exterior: | Dark Greenish Brown Liquid |
---|---|---|---|
Powder Exterior: | Light Yellow Powder | PH: | 4.5-8.5 |
Insolubles: | ≤0.05% | Fluorescence: | Strong |
Compatibility: | Not Change Chemicals Property | Yeast/Mold: | None |
Highlight: | c16h6na4o12s4,fluorescent tracer dye |
CAS 59572 10 0 Liguid Form Used as Water Treatment Chemicals in New Test Method
1. Description:
This product is a kind of fluorescent probe and PH indicator. It fluoresces blue in acidic solutions and in acidic organelles but fluoresces green in more basic organelles. This compound is potentially useful as a coloring agent, biological stain or optical detecting reagent. It is used in water-in-oil-in-water emulsions and as a substrate for lipase activity. Known as an inert fluorescent tracer, its fluorescence is strong. So 10PPB level of fluorescence signal can be detected by it, which helps to save water resources and manual processing cost. It is very popular especially in the North American market at present.
The traditional "adding chemicals一detection" method, the method of detecting drug concentration, obviously lags behind the current concentration in circulating water system. The new "detection一adding chemicals" method adopts real-time detection, and real-time PID operation is carried out between the reagent concentration of the current and the given one (P in PID regulator is a proportional procedure, magnifying function, I is an integral procedure, eliminating steady-state errors, D is a differential procedure, accelerating the reaction of system ), the result of operation can be output to control system in real time, and according to the result of PID operation, the control system can make flow control or state control of the dosing pump.
That is to say, in this way, we can first know whether there is a deviation between the composition of the medicine and the given value in the water, and then the system automatically adjusts. However, the instrument can not detect the composition of the reagent, it must rely on the fluorescence signal in the reagent (the instrument can only detect the fluorescence signal, and the intensity of the fluorescence signal is proportional to the dose of the chemicals), and it is the fluorescent tracer we produce that provides the fluorescence signal.
Compared with other fluorescent tracers (Naphthalene series, anthracene series), our fluorescent tracer has the characteristics of strong fluorescence signal and do not change chemical properties. The instrument can detect ppb level PTSA fluorescence signal, so it will not affect the water quality.
2. Specification:
No. | Test Items | Quality Index |
1 |
CAS No |
59572-10-0 |
2 | Molecular Weight | 610.43 |
3 | Content | 9.50-10.50% |
4 | Insolubles | ≤0.05% |
5 | Preservation | Store at room temperature |
6 | UV Absorance | 0.75-0.85 au |
7 |
Fluorescence |
λex 454 nm, λem 511 nm in water |
8 |
Heterophic bacteria |
None |
3. Structural Formula:
Standard:
A. Powder Form : content 98%
B. Liquid Form : content 10%
Contact Person: Ms. Chai
Tel: 18001549185
Fax: 86-0512-5779-6655