Product Details:
|
CAS NO.: | CAS No.59572-10-0 | Product Name: | PTSA;1,3,6,8-Pyrenetetrasulfonic Acid Tetrasodium Salt |
---|---|---|---|
Appearance: | Yellow Powder | Type: | Tracer Dye ; Inert Fluorescent Tracer |
PH: | 7.2 | Content: | 98% |
Moisture: | ≤0.05% | Insolubles: | ≤0.1% |
Molecular Weight: | 610.43 | Use: | Producing Fluorescent Signals Mixed With Boiler Water Chemicals |
Highlight: | CAS 59572-10-0 Fluorescent Tracer,PTSA Fluorescent Tracer,Water Treatment PTSA |
PTSA CAS 59572-10-0 Fluorescence Detection for Boiler Water Chemicals
1. Description:
Fluorescent tracer PTSA is used for various industrial circulating water systems. After the industrial circulating water is resolved, natural water enters the industrial cycle heat transfer system to improve the efficiency of equipment heat transfer, reduce equipment corrosion and improve the operating cycle. Its fluorescence is strong, and the instrument can detect a 10PPB level of fluorescence signal.
PTSA is an inert fluorescent tracer with a neutral pH and good compatibility with the drug. It will not react or be incompatible with the target drug. It also has no effect on the pH of the circulating water system.
2. Technical Data:
Chemical Name | 1,3,6,8-Pyrenetetrasulfonic acid tetrasodium salt |
Appearance | Light Yellow Powder |
Content | ≥98% |
PH | 4.5-8.5 |
Moisture | ≤0.05% |
CAS No. | 59572-10-0 |
Insolubles | 0.09 |
Molecular Weight | 610.43 |
PH | 7.2 |
Test Instrument | Ultraviolet Spectrophotometer |
Use | Mixed with water treatment chemicals including disinfectants, boiler water chemicals,scale inhibitors. |
3. Special Advantages of PTSA in Detection of Circulating Water:
a. Phosphorus-free water treatment chemicals must be used with fluorescent tracer: As the non-phosphorus water treatment chemicals can not be detected the concentration of phosphorus content. But with the help of signal from fluorescent tracer, the detection can be implemented successfully;
b. Saving processing costs: automatic online monitoring makes the water treatment chemicals achieve the most economic value, and also save a lot of manual testing costs;
c.Saving water resources: the use of fluorescent tracer with real-time PID operation, thus the water quality tend to achieve the best results, greatly reducing the number of emissions, also decreasing the amount of freshwater, to achieve the purpose of saving water resources.
4. Package:
Plastic bag lined cardboard drum, 25kg / drum
5. Structural Formula: