Product Details:
|
Liquid Exterior: | Dark Greenish Brown Liquid | Powder Exterior: | Light Yellow Powder |
---|---|---|---|
PH: | 4.5-8.5 | Insolubles: | ≤0.05% |
Physical Condition: | Liquid, Solid | Fluorescence: | Strong |
Compatibility: | Not Change Chemicals Property | Yeast/Mold: | None |
Highlight: | c16h6na4o12s4,fluorescent tracer dye |
CAS 59572 10 0 Saving Water and Energy with Timeliness of Detection in Industry
1. Description:
Firstly, it is widely used in various industrial circulating water treatment chemicals as a water treatment agent;
Secondly, it is a fluorescent tracer that is capable of being applied to engine lubrication, power steering, gearbox, hydraulic rotation, transfer pipelines or reservation equipment for cooling liquefied gas, air-tight circulating or non-circulation systems and so on in the field of aviation , ships, diesel locomotives, metallurgy, coal mining, refrigerating air-condition, heating, ventilation and air conditioning, petrochemical, engineering, machinery, other industries etc.
The traditional "adding chemicals一detection" method, the method of detecting drug concentration, obviously lags behind the current concentration in circulating water system. The new "detection一adding chemicals" method adopts real-time detection, and real-time PID operation is carried out between the reagent concentration of the current and the given one (P in PID regulator is a proportional procedure, magnifying function, I is an integral procedure, eliminating steady-state errors, D is a differential procedure, accelerating the reaction of system ), the result of operation can be output to control system in real time, and according to the result of PID operation, the control system can make flow control or state control of the dosing pump.
That is to say, in this way, we can first know whether there is a deviation between the composition of the medicine and the given value in the water, and then the system automatically adjusts. However, the instrument can not detect the composition of the reagent, it must rely on the fluorescence signal in the reagent (the instrument can only detect the fluorescence signal, and the intensity of the fluorescence signal is proportional to the dose of the chemicals), and it is the fluorescent tracer we produce that provides the fluorescence signal.
a. Phosphorus-free water treatment chemicals must be used with fluorescent tracer: As the non-phosphorus water treatment chemicals can not be detected the concentration of phosphorus content. But with the help of signal from fluorescent tracer, the detection can be implemented successfully;
b. Saving processing costs: automatic online monitoring makes the water treatment chemicals achieve the most economic value, and also save a lot of manual testing costs;
c. Saving water resources: the use of fluorescent tracer with real-time PID operation, thus the water quality tend to achieve the best results, greatly reducing the amount of emissions, also decreasing the amount of fresh water, to achieve the purpose of saving water resources.
2. Specification:
No. | Test Items | Quality Index |
1 |
CAS No |
59572-10-0 |
2 | Molecular Weight | 610.43 |
3 | Content | 9.50-10.50% |
4 | Insolubles | ≤0.05% |
5 | Preservation | Store at room temperature |
6 | UV Absorance | 0.75-0.85 au |
7 |
Fluorescence |
λex 454 nm, λem 511 nm in water |
8 |
Heterophic bacteria |
None |
3. Structural Formula:
Standard:
A. Powder Form : content 98%
B. Liquid Form : content 10%
4. REACH Certofocate:
5. SDS:
Contact Person: Ms. Chai
Tel: 18001549185
Fax: 86-0512-5779-6655